Rainwater Tank Size Calculator

Estimate a practical rainwater tank size for garden watering, shed collection or non-potable home use from dry-day demand, roof supply and overflow space.

Enter Storage And Supply Assumptions

A tank is not sized by annual rainfall alone. It must cover a chosen dry spell, fit the roof supply, leave overflow space during storms and still be practical to install. Use the defaults as a starting point, then replace them with local rainfall, roof area and real water use.

Litres per day for watering, cleaning or toilet flushing.

How long you want useful storage to last.

Extra percentage for unusable bottom water and planning margin.

m2 of roof draining to the tank.

mm of rain in a heavy event for overflow thinking.

Loss allowance before water reaches storage.

Choose the closest common tank size above the need.

Changes the installation note, not the litres.

Suggested Tank Capacity

Rounded tank size950 litres

Dry-spell storage needs 800 L plus 15% reserve, rounded up to 950 L.

Base dry-spell need
800 L
Reserve added
120 L
Heavy-rain inflow
700 L
Roof supply check
Good match
Fit overflow, leaf guards and a stable base. Tank size does not replace plumbing, structural or water-quality advice.

How To Read The Tank Size

The headline tank size is based on the number of dry days you want to cover. If you use about 80 litres per day and want ten dry days, the base storage need is 800 litres. The calculator then adds a reserve allowance for dead volume at the bottom of the tank, sediment, uneven use and a small planning margin. Finally it rounds up to a size that is closer to a real tank you could buy.

The roof supply check is separate. A 950 litre tank may look sensible for dry weather, but a small shed roof may not refill it often. A large roof may fill it rapidly and overflow during heavy rain. The storm inflow line shows how much water a selected rainfall event could send towards the tank before losses. This helps you think about downpipe capacity, overflow route and whether a bigger tank is useful or just expensive.

For garden-only systems, a tank often needs to be sized for summer, not annual rain. For toilet flushing or laundry systems, demand can be steadier through the year, so a larger tank may be used more often. Underground tanks and pumped systems can hold far more water, but they also cost more and need more maintenance.

Formula Used

Base dry-spell storage = daily demand x dry daysReserve litres = base dry-spell storage x reserve percentageUnrounded tank need = base dry-spell storage + reserve litresRounded tank size = next chosen rounding step above unrounded needStorm inflow litres = roof area m2 x storm rainfall mm x runoff coefficientSupply ratio = storm inflow / rounded tank size

The formula uses litres because one millimetre of rain over one square metre produces one litre. The dry-spell method is easy to check and avoids a common mistake: buying a tank based on one wet month without asking how long it should last in a dry spell.

Typical Tank Choices

Tank TypeTypical CapacityStrengthWatch Point
Slim water butt100 to 250 LLow cost and easy beside a shed or house wall.Runs dry quickly when watering beds in hot weather.
Large above-ground tank500 to 2,000 LGood for gardens and allotment style use.Needs a firm level base and a safe overflow route.
IBC containerAbout 1,000 LHigh volume for the price when suitable and clean.Must be food-safe or appropriate, screened from sun and safely supported.
Underground system1,500 L and aboveCan support year-round non-potable demand.Excavation, pump, filters, backflow protection and maintenance add cost.

Installation Checks

Base And WeightOne litre of water weighs about one kilogram. A full 1,000 L tank weighs about a tonne before the tank weight is added.
Overflow RouteEvery tank needs somewhere safe for excess water to go during heavy rain.
Leaf And Debris ControlGutter guards, first-flush devices and filters reduce blockages and smells.
Winter And AlgaeAbove-ground tanks may need frost protection, shade and cleaning access.

Place a water butt where the tap can fill a watering can without lifting strain. Larger tanks need safe access for inspection and cleaning. If the water is connected to toilets, washing machines or other indoor plumbing, use a suitable installer and follow water-supply backflow rules.

Worked Examples

A small shed roof with a 200 L water butt might be fine for topping up pots but weak for a vegetable bed in July. A 35 m2 roof and 950 L tank can support a more serious garden plan, but it still depends on rainfall timing. A toilet-flushing system may use rainwater throughout the year, so the tank can be larger and more costly, with a pump and filters included in the design.

If the result suggests a very large tank, check whether daily demand is realistic. Garden watering can be cut with mulch, drip irrigation, drought-tolerant planting and watering at cooler times. A smaller tank plus lower demand can be better value than a large tank used only a few times each summer.

FAQ

What size rainwater tank do I need for a garden?

Start with daily watering demand and the number of dry days you want to cover. A small patio may need only 100 to 250 L, while vegetable beds can justify 500 L or more if the roof supply is good.

Can a tank be too big?

Yes. An oversized tank can cost more, take space and hold stale water if demand is low. Match storage to demand, roof supply and overflow plans.

Should I size by annual rainfall?

No. Annual rainfall is useful for supply, but tank size is often decided by dry spells and usable demand. A wet winter does not water a garden in a dry summer unless storage is available.

How much does 1,000 litres weigh?

About 1,000 kg, before the tank and base are counted. Large tanks need a stable, level support and suitable ground.

Does the calculator include pump sizing?

No. It estimates storage volume. Pump flow, pressure, filters and backflow protection need product and installation advice.

Can I use harvested rainwater indoors?

Only with a suitable non-potable system, correct labelling, filters, backflow protection and maintenance. Do not connect rainwater to drinking-water outlets.

Sources

  1. Environment Agency. (n.d.). Rainwater Harvesting: An On-Farm Guide. GOV.UK. https://www.gov.uk/government/publications/rainwater-harvesting-an-on-farm-guide
  2. Met Office. (n.d.). UK Climate Averages. Met Office. https://www.metoffice.gov.uk/research/climate/maps-and-data/uk-climate-averages
  3. Energy Saving Trust. (n.d.). Saving Water At Home. Energy Saving Trust. https://energysavingtrust.org.uk/advice/saving-water-at-home/
  4. Water Regulations Advisory Scheme. (n.d.). Water Regulations Guidance. WRAS. https://www.wrasapprovals.co.uk/
Scroll to Top