Wheelchair Ramp Gradient Calculator UK

Calculate ramp gradient, angle, required run and practical landing checks from the rise height and available ramp length.

Enter Rise And Ramp Run

Height from lower level to upper level. Unit: mm.
Sloping length or horizontal run depending on your measuring method. Unit: metres.
At top or bottom. Unit: metres.

Ramp Gradient Result

1:0

Gradient shown as one unit of rise for every number of units of run.

What The Ramp Result Means

A ramp gradient written as 1:15 means the ramp rises 1 unit for every 15 units of run. A larger second number is gentler. For example, 1:20 is gentler than 1:12. The calculator converts your rise and run into a ratio, an angle in degrees, a percentage gradient and three comparison lengths: how much run would be needed for 1:20, 1:15 and 1:12.

The result is a measurement and planning aid, not a building approval. UK access design can depend on the building type, existing constraints, handrails, landings, crossfall, surface, weather exposure, door swing, edge protection, lighting and who will use the ramp. A ramp that passes a simple gradient check can still be unsafe or non-compliant if landings, guarding or surface conditions are poor.

Formula And Measuring Method

Rise in metres = rise in millimetres / 1000.

If horizontal run is entered, gradient ratio = horizontal run / rise in metres.

If sloping length is entered, horizontal run = square root of sloping length squared – rise squared.

Gradient percent = rise in metres / horizontal run x 100.

Angle in degrees = arctangent of rise divided by horizontal run.

Required run for 1:20 = rise in metres x 20.

Required run for 1:15 = rise in metres x 15.

Required run for 1:12 = rise in metres x 12.

Use a tape measure and a level where possible. For a doorway threshold, measure from the finished lower surface to the finished upper surface, not from a loose mat or a temporary board. For an outdoor ramp, check the actual landing surfaces because paving slope and drainage can change the useful run.

UK Access Guidance Comparison

GradientMeaningPlanning NoteWhy It Matters
1:20 or gentlerVery shallow ramp relationship.Often treated as easier for many users, though landings and length still matter.More space is needed, but pushing effort is lower.
1:15Moderate ramp relationship.Often appears in access guidance with length limits and landings.Can be workable for short rises but may tire users.
1:12Steeper practical upper check.Usually only considered for short rises and controlled settings.Harder for manual wheelchair users and carers.
Steeper than 1:12Very steep for wheelchair access.Seek specialist advice or a different approach.Risk of loss of control, grounding, slipping or excessive effort.

Worked Ramp Examples

75 mm Door Threshold

A 75 mm rise needs 1.5 m of run for a 1:20 check, 1.125 m for 1:15 and 0.9 m for 1:12. A small threshold can still need a surprisingly long ramp if the user is self-propelling.

300 mm Step Into A Porch

A 300 mm rise needs 6 m of run at 1:20, 4.5 m at 1:15 and 3.6 m at 1:12. This is where landings, turning space and door swing often control the design.

Temporary Event Ramp

A portable ramp may be allowed by an event supplier for a short controlled use, but steep portable ramps can be difficult, especially in rain. Check weight limits, edge protection and trained assistance.

Landing, Surface And Safety Checks

Gradient is only one part of ramp usability. Level landings let a wheelchair user pause, open a door, turn or recover control. A ramp that ends directly at a door threshold, gate, pavement edge or car parking bay may be difficult even when the calculated gradient looks acceptable. The landing length field does not prove compliance; it prompts you to check whether the ramp has usable level space at both ends.

Surface matters as much as length. Outdoor ramps need slip-resistant materials, drainage, edge protection and lighting. Timber can become slippery, metal can be noisy or cold, and loose mats can move under small front wheels. Handrails may be needed, especially where the ramp is long, exposed, used by the public or has a drop at the side.

If the result is too steep, do not simply add grip tape and carry on. Consider a longer ramp, a switchback layout, platform lift, door alteration, threshold reduction, different entrance, regrading the path or professional access advice. For rented homes, workplaces, schools, care settings and public buildings, duties and approval routes can be separate from the arithmetic.

Recording Measurements For A Quote

When asking a builder, access consultant or supplier for advice, send more than the ratio. Record the rise, the available horizontal run, doorway width, landing depth, surface material, drainage direction and any side drop. Add photographs from the lower approach, upper landing and side view. A clear measurement pack helps the supplier spot whether a straight ramp, return ramp, platform lift or threshold alteration is the more realistic option.

If the ramp will be used by a powered chair, scooter, attendant-propelled chair or walking frame, state that as well. Turning radius, wheelbase, ground clearance and user stamina can change the design even when the same 1:15 ratio appears on paper.

FAQ

What does a 1:12 ramp mean?

It means 1 unit of rise for every 12 units of run. For a 100 mm rise, a 1:12 ramp needs about 1.2 m of run.

Is 1:20 better than 1:12?

Yes, it is gentler because the ramp rises more slowly. It needs more space, but it is usually easier for many wheelchair users.

Does the calculator prove Building Regulations compliance?

No. It calculates geometry only. Compliance can depend on building type, landings, handrails, surface, doors, edge protection and professional judgement.

Should I measure ramp length along the slope or horizontally?

Use the selector that matches your measurement. Horizontal run is the usual ratio basis; if you enter sloping surface length, the script estimates the horizontal run.

How long should a ramp be for a 300 mm rise?

For 300 mm rise, a 1:20 check needs 6 m, 1:15 needs 4.5 m and 1:12 needs 3.6 m before landing and layout details are considered.

What if there is not enough space for a safe ramp?

Look at a different entrance, regrading, a platform lift, threshold works or specialist access advice. Do not rely on a very steep ramp for regular independent use.

Sources

  • Ministry of Housing, Communities and Local Government. (2021). Approved Document M: Access to and Use of Buildings, Volume 1. GOV.UK. https://www.gov.uk/government/publications/access-to-and-use-of-buildings-approved-document-m
  • Ministry of Housing, Communities and Local Government. (2021). Approved Document M: Access to and Use of Buildings, Volume 2. GOV.UK. https://www.gov.uk/government/publications/access-to-and-use-of-buildings-approved-document-m
  • Health and Safety Executive. (n.d.). Slips and Trips: Floors, Stairs and Ramps. HSE. https://www.hse.gov.uk/slips/
Scroll to Top