Weber To Maxwell Converter

Convert magnetic flux between webers and maxwells, with optional flux density and coil voltage helpers for engineering notes and lab records.

Convert Magnetic Flux

Scientific notation such as 1e-6 is accepted by most browsers.
Square metres. Leave as 0 if not needed.
Seconds for a simple average induced-voltage check.

Magnetic Flux Result

0 Mx

Direct SI and CGS magnetic flux conversion.

SI unit: WbCGS unit: Mx

Direct Weber And Maxwell Answer

One weber equals 100,000,000 maxwells. Written in scientific notation, 1 Wb = 1e8 Mx. The reverse conversion is 1 Mx = 1e-8 Wb. The large factor exists because the weber is the SI magnetic flux unit and the maxwell belongs to the centimetre-gram-second electromagnetic unit system.

The converter is useful when older magnetics papers, instrument manuals, motor notes or archived laboratory records use maxwells while a modern calculation, simulation or data sheet uses webers. It also helps when a value is so large or small that scientific notation is clearer than a long string of zeros.

Conversion Formula And Method

Maxwells = webers x 100,000,000.

Maxwells = webers x 1e8.

Webers = maxwells / 100,000,000.

Webers = maxwells x 1e-8.

Flux density in tesla = webers / area in m2.

Average induced voltage = coil turns x change in webers / seconds.

The last two lines are optional helpers. They do not change the weber-to-maxwell conversion. They simply show related values that often appear beside magnetic flux: tesla for flux density over an area, and a basic Faraday-law average voltage when flux changes through a coil.

Quick Conversion Table

WebersMaxwellsCommon notationComment
1 Wb100,000,000 Mx1e8 MxLarge SI flux value in many bench contexts.
0.01 Wb1,000,000 Mx1e6 MxUseful for checking decimal placement.
0.001 Wb100,000 Mx1e5 MxOne milliweber in SI prefix form.
0.000001 Wb100 Mx1e2 MxOne microweber, written without a micro symbol for ASCII output.
0.00000001 Wb1 Mx1e0 MxThe reverse anchor point for one maxwell.

Worked Magnetic Flux Examples

Old Record Gives 250,000 Mx

Divide by 100,000,000. The SI value is 0.0025 Wb, or 2.5e-3 Wb. If the record also states a coil area, divide webers by that area to get a tesla value.

Simulation Gives 4e-6 Wb

Multiply by 1e8. The CGS value is 400 Mx. The converter keeps the exact direction clear so the factor is not accidentally applied twice.

Coil Change Check

If 1e-6 Wb changes through 100 turns in 0.5 seconds, the simple average induced voltage is 0.0002 V. Real waveforms, sign convention and circuit loading can differ.

Unit Notes For Engineering Use

Use webers when you want SI consistency with tesla, volt seconds, metres, amperes and modern engineering equations. Use maxwells only when the source material uses the CGS unit or when you need to reproduce an older table. Mixing SI and CGS magnetic units can create large errors, so carry the unit label into your notes, spreadsheet headings and graph axes.

Be careful with magnetic flux density and magnetic flux. A weber is total flux. A tesla is flux per square metre. If an instrument reports gauss, that is a flux density unit, not a maxwell. The converter does not turn gauss into maxwells unless an area is known, because flux density multiplied by area is what gives flux.

For coil calculations, the sign of induced voltage depends on the chosen direction and Lenz’s law. The helper gives a magnitude from turns, flux change and time only. It is a rough arithmetic check, not a circuit simulation.

Common Mistakes To Check

The most common error is moving the decimal point by eight places in the wrong direction. When going from webers to maxwells, the number becomes larger. When going from maxwells to webers, the number becomes smaller. A second error is confusing milliweber and microweber: 0.001 Wb is 100,000 Mx, while 0.000001 Wb is only 100 Mx.

Another common error is treating maxwell and gauss as interchangeable. They are related only through area. A field of 1 gauss over 1 square centimetre corresponds to 1 maxwell of flux, but change the area and the flux changes. If your source gives a field strength or flux density, check whether it is in tesla or gauss before using this page.

Notation Checklist For Reports

Magnetic flux values can look harmless until they are copied into a report, graph label or spreadsheet column without the unit. Use Wb for webers and Mx for maxwells, and add scientific notation when a value needs more than three or four zeros. A column headed only “flux” is risky because readers cannot tell whether 100 means 100 Wb, 100 Mx or 100 microwebers. The converter output gives both the ordinary label and the compact notation so you can paste the safer form into notes.

If you are preparing a table from older CGS material, keep the original maxwell value in one column and the converted SI value in another. That makes checking easier for colleagues who still have the source paper open. If you are moving the other way, state that the maxwell number is a converted value and not the unit used by the instrument.

For graphs, choose a prefix before plotting. A set of values near 0.000001 Wb may be clearer as microwebers in a caption, while the same values in maxwells may be easier as hundreds of Mx. The correct choice is the one that reduces decimal mistakes without hiding the base relationship: 1 Wb equals 100,000,000 Mx.

FAQ

How many maxwells are in one weber?

One weber is 100,000,000 maxwells, or 1e8 Mx.

How many webers are in one maxwell?

One maxwell is 0.00000001 weber, or 1e-8 Wb.

Is maxwell an SI unit?

No. Weber is the SI magnetic flux unit. Maxwell is a CGS magnetic flux unit found in older and specialised material.

Can I convert gauss with this page?

Not directly. Gauss is flux density. To get flux, you also need the area the field passes through.

Why does the result use scientific notation?

The conversion factor is 100 million, so scientific notation reduces zero-counting mistakes and makes very small values easier to read.

Does the coil voltage helper replace Faraday-law analysis?

No. It gives a simple average magnitude from turns, flux change and time. Real circuits need waveform, polarity, loading and geometry checks.

Sources

  • Bureau International des Poids et Mesures. (2025). The International System of Units, 9th Edition. BIPM. https://www.bipm.org/en/publications/si-brochure
  • National Institute of Standards and Technology. (2008). Guide for the Use of the International System of Units. NIST Special Publication 811. https://www.nist.gov/pml/special-publication-811
  • International Electrotechnical Commission. (n.d.). Electropedia: Magnetic Flux And Weber. IEC. https://www.electropedia.org/